Eldes EKB3 Manuale di Installazione Pagina 106

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 168
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 105
106
106 EN
MANUAL ELDES ESIM264 V3.1
Due to the individual conguration of each monitoring station, the system may fail to deliver the data message via Voice Calls communi-
cation method. In such cases it is recommended to adjust the microphone gain until the optimal value, leading to successful data message
delivery, is discovered.
Set microphone gain
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETT INGS OK GSM AUDIO OK
MICROPHONE GAIN OK mg OK
Value: aaaa – 4-digit administrator password; mg – microphone gain, range – [0... 15].
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
30.2.3. CSD
The system supports up to 5 monitoring station phone numbers for communication with the alarm system by CSD communication method.
Tel. Number 1 is mandatory, the other four can be used as backup phone numbers and are not necessary. The supported phone number
format is the following:
International (w/o plus) – The phone numbers must be entered starting with an international country code in the following format:
[international code][area code][local number], example for UK: 4417091111111.
To set up the system for data transmission via CSD, please follow the basic conguration steps:
1. Enable MS Mode parameter (see 30. MONITORING STATION).
2. Set 4-digit Account number (see 30. MONITORING STATION).
3. Set Tel. Number 1... 5.
Set monitoring station
phone number
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK CSD SETTINGS OK
TEL. NUMBER 1... 5 OK ttteeellnnuumm OK
Value: aaaa – 4-digit administrator password; ttteeellnnuumm – up to 15 digits monitoring
station phone number.
EKB3
Enter parameter 85, number of entry & phone number:
85 ps ttteeellnnuumm #
Value: ps – phone number slot, range – [01... 05]; ttteeellnnuumm – up to 15 digits monito-
ring station phone number.
Example: 85014417091111111#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Delete monitoring
station phone number
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK CSD SETTINGS OK
TEL. NUMBER 1... 5 OK OK
Value: aaaa – 4-digit administrator password.
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Vedere la pagina 105