17. ALARM INDICATIONS AND NOTIFICATIONS
When a zone, depending on zone type (see 14.5. Zone Type Denitions), or tamper is violated, the system will cause an alarm. By de-
fault, the alarm duration is 1 minute (see 20. SIREN/BELL regarding the alarm duration). During the alarm, the system will follow this
pattern:
1. The system activates the siren/bell and the keypad buzzer.
a) The siren/bell will emit pulsating sound if the violated zone is of Fire type, otherwise the sound will be steady.
b) The keypad buzzer will emit short beeps.
c) Depending on violated zone type, EKB2 keypad will display BURGLARY ALARM message followed by one of the alarm messages in the
home screen view:
• ALARM.
• FIRE ALARM.
• 24H ALARM.
d) During the tamper alarm, EKB2 keypad will display TAMPER ALARM message in the home screen view.
e) If one or more zones are violated, EKB3 will light ON the corresponding violated zone indicator (-s) ranging from 1 through 12. Indica-
tor SYSTEM will ash if one or more high-numbered zones are violated. If one or tampers are violated, indicator SYSTEM will light ON.
For more details on viewing violated high-numbered zone and tamper numbers by EKB3 keypad, please refer to 29. INDICATION OF
SYSTEM FAULTS.
2. The system attempts to send an SMS text message, containing the violated zone/tamper name (see 14.8. Zone Names on how to set
a zone name), to the rst preset user phone number, sharing the same partition as the violated zone/tamper. The system will send SMS
text messages regarding each violated zone/tamper separately.
a) If the user phone number is unavailable and the system fails to receive the SMS delivery report during 20 seconds, it will attempt to
send the SMS text message to the next preset user phone number, assigned to the same partition as the previous one. The user phone
number may be unavailable due to the following reasons:
• mobile phone was switched o.
• was out of GSM signal coverage.
b) The system will continue sending the SMS text message to the next preset user phone numbers in the priority order until one is avail-
able. The system sends the SMS text message only once and will not return to the rst user phone number if the last one was unavail-
able.
3. If enabled, the system attempts to ring the rst user phone number, sharing the same partition as the violated zone/tamper. The system
will dial regarding each violated zone/tamper separately.
a) When the call is answered, the user will be able to listen on the mobile phone for approx. 30 seconds to what is happening in the area,
surrounding the alarm system. This feature will be available only if a microphone is connected to the system (see 25. REMOTE LIS-
TENING AND 2-WAY VOICE COMMUNICATION).
b) The system will dial the next preset user phone number, assigned to the same partition, if the previous user was unavailable due to the
following reasons:
• mobile phone was switched o.
• mobile phone was out of GSM signal coverage.
• provided “busy” signal.
• user did not answer the call after several rings, predetermined by the GSM operator.
c) The system will continue dialing the next preset user phone numbers in the priority order until one is available. The system dials only
once and will not return to the rst user phone number if the last one was unavailable.
d) The system will not dial the next preset user phone number if the previous one was available, but rejected the phone call.
To silent the siren/bell as well as to cease system phone calls and SMS text message sending to the user phone numbers, please disarm the
system (see 12. ARMING AND DISARMING).
View violated zones
SMS
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
EKB2
Menu path:
OK → VIOLATED ZONES → OK → ZONE 1... 44