30.1. Data Messages – Events
The conguration of data messages is based on Ademco Contact ID protocol. The data messages can either be transmitted to the monitor-
ing station alone or with duplication by SMS text message to preset user phone number. For more details on system notications by SMS
text message, please refer to 27. SYSTEM NOTIFICATIONS.
Seq. No. Contact ID® Code Event Description
1 1110 Fire alarm Transmitted in case a zone of Fire type is violated.
2 3110 Fire restore Transmitted in case a zone of Fire type is restored.
3 1121 Disarmed by user (Duress
password)
Transmitted in case the system is disarmed by Duress password.
4 1130 Burglary alarm Transmitted in case a zone of Delay (if not disarmed before entry delay
countdown is completed), Interior Follower or Instant type is violated.
5 3130 Burglary restore Transmitted in case a zone of Delay (if not disarmed before entry delay
countdown is completed), Interior Follower or Instant type is restored.
6 1133 24-Hour zone alarm Transmitted in case of zone of 24-Hour type is violated.
7 3133 24-Hour zone restore Transmitted in case of zone of 24-Hour type is restored.
8 1144 Tamper alarm Transmitted in case the tamper is violated.
9 3144 Tamper restore Transmitted in case the tamper is restored.
10 1146 Panic/Silent zone alarm Transmitted in case of zone of Panic/Silent type is violated.
11 3146 Panic/Silent zone restore Transmitted in case of zone of Panic/Silent type is restored.
12 1158 Temperature risen Transmitted in case of the temperature has increased above the MAX set
value.
13 1159 Temperature fallen Transmitted in case of temperature has decreased below the MIN set value.
14 1301 Mains power loss Transmitted in case the main power supply is lost.
15 3301 Mains power restore Transmitted in case the main power supply is restored.
16 1302 Low battery Transmitted in case the backup battery voltage is 10.5V or lower / the
wireless sensor battery level runs below 5%.
17 1308 System shutdown When the system is running on backup battery power, it transmits the data
message before the backup battery power is fully depleted.
18 1309 Battery failed Transmitted in case the backup battery resistance is 2 or higher.
19 1358 GSM connection failed Transmitted in case the GSM connection is lost.
20 1381 Wireless signal loss Transmitted in case the connection with any wireless device is lost.
21 3381 Wireless signal restore Transmitted in case the connection with any wireless device is restored.
22 1401 Disarmed by user Transmitted in case the system is disarmed.
23 3401 Armed by user Transmitted in case the system is armed.
24 1456 Disarmed in Stay mode Transmitted in case the system is disarmed in Stay mode.
25 3456 Armed in Stay mode Transmitted in case the system is armed in Stay mode.
26 1463 Disarmed by user (SGS
password)
Transmitted in case the system is disarmed by SGS password.
27 3463 Armed by user (SGS
password)
Transmitted in case the system is armed by SGS password.
28 1602 Test event/Kronos ping Transmitted for system online status verication purposes.
29 3626 Date/time not set Transmitted in case system date & time is not set.
30 1900 System started Transmitted on system startup.