MANUAL ELDES ESIM264 V3.1
NOTE: PGM output can be turned ON for a determined time period only when it is in OFF state
NOTE: PGM output can be turned OFF for a determined time period only when it is in ON state
NOTE: Multiple PGM outputs can be turned ON/OFF by a single SMS text message, Example: 1111_C1:ON C2:OFF Pump:ON C4:ON:00.20.25
18.5. PGM Output Control by Event and Scheduler
The PGM outputs can automatically operate when a specic event occurs in the system and/or when the scheduled weekday and time
comes.
PGM Output Actions
The automatic action of the determined PGM output can be set as follows:
• Turn ON – Determines whether the PGM output is to be turned ON.
• Turn OFF – Determines whether the PGM output is to be turned OFF.
• Pulse – Determines whether the PGM output is to be turned ON for a set period of time in seconds.
System Events
The aforementioned PGM output action can be automatically carried out under the following events that have occurred in the system:
• System armed – System is armed in a determined partition ranging from Partition 1 through 4 or any partition.
• System disarmed – System is disarmed in a determined partition ranging from Partition 1 through 4 or any partition.
• Alarm begins – Alarm begins in a determined partition ranging from Partition 1 through 4 or any partition.
• Alarm stops – Alarm stops in a determined partition ranging from Partition 1 through 4 or any partition.
• Temperature falls – Temperature falls below the set MIN value of a determined temperature sensor 1-8.
• Temperature rises – Temperature rises above the set MAX value of a determined temperature sensor 1-8.
• Zone violated – A determined zone ranging from Z1 through Z76 is violated.
• Zone restored – A determined zone ranging from Z1 through Z76 is restored.
• Scheduler starts – Determines Start Time of a selected scheduler 1-16.
• Scheduler ends – Determines End Time of a selected scheduler 1-16.
The user can also set a custom text, which will be sent by SMS text message to user phone number when the automatic PGM output action
is carried out.
Schedulers
The system supports up to 16 schedulers that allow the PGM outputs to operate according to the day of the week and time. When the
scheduler, which includes the set weekday and time, is selected, the PGM output will operate according to it. Each scheduler includes the
following parameters:
• Always – The scheduler is not in use.
• At specied time – Determines whether weekday and time settings are enabled:
• Start Time – Determines the point in time when the PGM output action can begin.
• End Time – Determines the point in time when the PGM output action can complete.
• On weekdays – Determines days in week when the PGM output action is valid.
Additional Conditions
Additional condition narrows down the chances for a determined automatic PGM output operation to be carried out. If this feature is en-
abled, the PGM output will become dependent on one more system event that must be occurred prior or must occur after the aforemen-
tioned system event. The PGM output will not operate until the chain of system events meets the set values:
• System armed – System is armed in a determined partition ranging from 1 to 4 or any partition.
• System disarmed – System is disarmed in a determined partition ranging from 1 to 4 or any partition.
• Zone violated – A determined zone ranging from Z1 to 76 is violated.
• Zone restored – A determined zone ranging from Z1 to Z76 is restored.
Example: PGM output C1 is set to be turned ON when zone Z6 is violated. The additional condition feature is enabled and set to allow this
action to be carried out only if system’s Partition 2 is disarmed. It means that the PGM output C1 will be turned ON when zone Z6 is violated,
but only if system’s Partition 2 is disarmed.